Lab Test Directory

Menu
  • Home
  • Laboratory Solutions
    • Lab Test Directory
  • Strategic Alliances
  • Provider Portal
  • Order Supplies
  • Online Payment
  • Patient Education
    • Fasting & Glucose
    • 24-Hour Urine
    • Stool Samples
  • Contact Us
    • Online Booking

Keywords

Filter

  • All
  • A
  • B
  • C
  • D
  • E
  • F
  • G
  • H
  • I
  • J
  • K
  • L
  • M
  • N
  • O
  • P
  • Q
  • R
  • S
  • T
  • U
  • V
  • W
  • X
  • Y
  • Z
  • #

Test Listing: Total Bilirubin

Analyzer
Abbrev TBIL
Analyte Total Bilirubin
Department Chemistry-General
Specimen Type Serum
Alternate Specimen Type N/A
Specimen Stability Requirements Transport refrigerated in the light-protected container within 3 days after collection
Preferred Specimen 1mL Serum
Minimum Volume 0.5mL
Collection Instructions Protect from light. Avoid hemolysis.
Specimen Instructions Allow serum samples to clot completely before centrifugation. Serum gel tubes (SSTs) should be centrifuged within 2 hours of collection. Protect from light by wrapping SSTs in foil. Red-top tubes should be centrifuged and aliquoted to a light protected plastic transport tube within 2 hours of collection. Avoid hemolysis. Gel tubes should be spun at room temperature at a speed of 1000 to 1300 RCF for 10 minutes in a swinging bucket centrifuge and 15 minutes in a fixed-angle centrifuge. Non-gel serum tubes can be centrifuged at ≤ 1300 RCF for 10 minutes. After centrifugation refrigerates the samples at 2 to 8°C.
Reasons for Rejection Improper labeling; improper collection and storage; quantity not sufficient for analysis; improper specimen type; expired stability; gross hemolysis.
CPT Code 82247

Test Listing: Total Bilirubin

Analyzer
Abbrev TBIL
Analyte Total Bilirubin
Department Chemistry-General
Specimen Type Serum
Alternate Specimen Type N/A
Specimen Stability Requirements Transport refrigerated in the light-protected container within 3 days after collection
Preferred Specimen 1mL Serum
Minimum Volume 0.5mL
Collection Instructions Protect from light. Avoid hemolysis.
Specimen Instructions Allow serum samples to clot completely before centrifugation. Serum gel tubes (SSTs) should be centrifuged within 2 hours of collection. Protect from light by wrapping SSTs in foil. Red-top tubes should be centrifuged and aliquoted to a light protected plastic transport tube within 2 hours of collection. Avoid hemolysis. Gel tubes should be spun at room temperature at a speed of 1000 to 1300 RCF for 10 minutes in a swinging bucket centrifuge and 15 minutes in a fixed-angle centrifuge. Non-gel serum tubes can be centrifuged at ≤ 1300 RCF for 10 minutes. After centrifugation refrigerates the samples at 2 to 8°C.
Reasons for Rejection Improper labeling; improper collection and storage; quantity not sufficient for analysis; improper specimen type; expired stability; gross hemolysis.
CPT Code 82247
Company
  • Home
  • Laboratory Solutions
    • Lab Test Directory
  • Strategic Alliances
  • Provider Portal
  • Order Supplies
  • Online Payment
  • Patient Education
    • Fasting & Glucose
    • 24-Hour Urine
    • Stool Samples
  • Contact Us
    • Online Booking

Laboratory Solutions
  • Ortho/Neuro/Spine
  • Women’s Health
  • Psychiatry & Mental Health
  • Primary Care
  • Patient Medication Monitoring
  • Pain Management
  • Blood Wellness Testing
  • Lab Services
contact us

info@precisionlabservices.com

806.771.9988
Billing: 469.995.8198

© 2018 | Precision Lab Services, LLC. A Quality Metrics Partners company | All Rights Reserved